View the webinars Rational use of dynamic light scattering for the characterization of cytokines, bispecific antibody fusion proteins and binary antibody mixtures and Predicting stability of antibody therapeutics by unfolded-state studies with high-throughput dynamic light scattering (HT-DLS) for more information.Īntibody-drug conjugates (ADCs) are important biotherapeutic candidates that combine highly potent cytotoxic drugs with monoclonal antibodies (mAb) for targeted drug delivery in the treatment of cancer or neurodegenerative disorders. DLS is crucial to understanding the thermal and long-term stability of therapeutically relevant proteins in different formulation conditions. The rational biophysical characterization of therapeutic protein candidates and their formulations can greatly improve the early-stage development process of new biologics.

MALVERN ZETASIZER ADD REFRACTIVE INDEX SOFTWARE
Moreover, DYNAMICS ® software contains an extensive, built-in solvent library with the most common solvents and buffer systems, including the option to create custom solvents.

Pre-screening: Ideal to check sample quality before running other expensive and time-consuming biophysical methods such as TEM, AUC, SAXS/SANS, FFF and SEC.įor in-depth characterization of high-resolution size distributions and other physical properties, SEC-MALS and FFF-MALS offer complementary and orthogonal techniques to DLS.ĭLS determines the hydrodynamic size of a nanoparticle in solution by measuring the time scale of Brownian motion.Advanced properties: Measure particle concentration, nonspecific interactions ( A 2 or B 22) and differentiate between conformational changes and aggregation with the static light scattering option in the NanoStar and Plate Reader.Versatility: Beyond size and size distributions, measure other properties such as stability, stress-induced aggregation and molecular interactions.No shearing or filtering: always measure what’s in your solution.Low sample volume: Only 2 µL in the DynaPro NanoStar using quartz cuvettes, 4 µL in disposable cuvettes or standard microwell plates in the DynaPro Plate Reader.Non-destructive and fully recoverable: Samples may be transferred to other assays.
MALVERN ZETASIZER ADD REFRACTIVE INDEX FULL
Full nanometer size range: from 0.5 nm to 2.5 µm in a single measurement, with a resolution up to a factor of 3-5 in size.Dynamic & Electrophoretic Light ScatteringĭLS is an ideal screening tool for biopharmaceutical formulations and other nanomaterials.